[Home ] [Archive]   [ فارسی ]  
:: Main Online Submission Archive Current Issue In Press ::
:: Volume 15, Issue 4 (Clinical Science Issue - April 2013) ::
ZJRMS 2013, 15(4): 43-47 Back to browse issues page
Reliability of the Center of Pressure Parameters after ACL Reconstruction Surgery
Hoda Niknam , Alireza Sarmadi , Mahiar Salavati , Firooz Madadi
Department of Physiotherapy, Tarbiat modares University, Tehran, Iran , hodaniknam@gmail.com
Abstract:   (5600 Views)
Background : The elicited parameters from the center of pressure (COP) of patients after surgery of the anterior cruciate ligament are proper indications for estimating balance after surgery and rehabilitation. Thus, making sure about repeatability of COP parameters which can determine the knee joint after the knee reconstruction surgery is very important. This study measures repeatability rate of some COP parameters after reconstructing anterior cruciate ligament in various positions.
Materials and Methods : In this study, 15 athlete men (mean age: 27±5) after 4-6 months since repair of their anterior cruciate ligament were included they have been selected through simple non-probability sampling method. The study was conducted in biomechanics lab of Tarbiat Modares University in 2010. Assessment of balance was done with open/closed eyes, with/without foam using force platform in two sessions with 48 hours interval.
Results : The external-internal amplitude (0.86), external-internal standard deviation (0.86), phase plane (0.82) and area oscillation (0.81) were among parameters which showed the most repeatability. The average oscillation of anterior - posterior frequency (0.6) showed the lowest repeatability.
Conclusion : A number of parameters caused by oscillation of COP show high rate of repeatability after reconstructing anterior cruciate ligament which can be used as an assessment of patients condition after reconstruction of the anterior cruciate ligament.
Keywords: Reliability, ACL, Center of pressure
Full-Text [PDF 150 kb]   (1477 Downloads)    
Type of Study: Research | Subject: Physiotherapy
Send email to the article author

Add your comments about this article
Your username or Email:

Write the security code in the box >


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Niknam H, Sarmadi A, Salavati M, Madadi F. Reliability of the Center of Pressure Parameters after ACL Reconstruction Surgery. ZJRMS. 2013; 15 (4) :43-47
URL: http://zjrms.ir/article-1-1102-en.html


Volume 15, Issue 4 (Clinical Science Issue - April 2013) Back to browse issues page
Zahedan Journal of Research in Medical Sciences
Persian site map - English site map - Created in 0.06 seconds with 31 queries by YEKTAWEB 3705