The assessment of the difference of capillary blood glucose level and venous glucose level measured by glucometer devices
Abstract:   (18205 Views)
Bastanhagh MH. MD*, Larijani B. MD*, Khalili Fard AR. MD*
Hossein Nezhad A. MD*, Shafahi AR. MD*
Today, increasing the prevalence of diabetes mellitus is an important problem in
glucose developing country’s Health and the blood glucose monitoring predicts of in
sufficient blood glucose monitoring side effects. The glucometer devices are small and
used simply so they are used more than the other methods for home blood glucose
monitoring. As the variety of the glucometer devices are increasing from day to day.
In this study, we assess the difference of capillary glucose level and venous glucose
level measured by three glucometer devices; Glucotrend 2, GlucoMen, GlucoCare. 100
diabetic patients took part in this study.
The results of 100 patients study, showed that the venous blood glucose level
measured by these devices with compare of standard method were 2.14% in GlucoCare,
5.3% in Glucotrend 2 and 17.1% in GlucoMen more than the standard level.
The GlucoCare and Glucotrend 2, results had no difference with the standard method
and the blood glucose levels measured with these two devices were similar. Otherwise the
GlucoMen results are more similar to standard method, it has the least confident.
The GlucoCare had the least deference of the mean venous glucose level with the
standard method and the most similarity between the capillary glucose level and venous
glucose level measured by these devices were seen in Glucotrend 2.
KEY WORDS: glucometer, capillary glucose, venous glucose
* Endocrinology and Metabolism Research Center, Tehran University of Medical Sciences and
health services, Tehran, Iran.
Keywords: glucometer, capillary glucose, venous glucose
Full-Text [PDF 193 kb]   (1026 Downloads)    
Type of Study: Research |
Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

The assessment of the difference of capillary blood glucose level and venous glucose level measured by glucometer devices. ZJRMS. 2003; 5 (2) :9-15
URL: http://zjrms.ir/article-1-7-en.html


Volume 5, Issue 2 (Jun 2003) Back to browse issues page
Zahedan Journal of Research in Medical Sciences
Persian site map - English site map - Created in 0.05 seconds with 31 queries by YEKTAWEB 3921