بررسی مقایسه ای کارایی منعقد کننده های سولفات آلومینیوم، کلراید فریک و پلی آلومینیوم کلرایددر حذف کدورت از آب آشامیدنی
کردمصطفی پور فردوس، بذرافشان ادریس، کمانی حسین
چکیده:   (6902 مشاهده)
 
Kord Mostafapoor F, MD*; Bazrafshan E, MD*; Kamani H, MSc*
 
Background: Since Coagulation and flocculation are essential processes for turbidity removal from drinking water, many studies have been conducted on different coagulant.
Materials and Methods: The present study - a pilot scale experiment- was conducted in the laboratory of water and wastewater chemistry of Zahedan public health school in 2007 to compare the efficiency of PAC, Ferric chloride and aluminum sulfate as coagulants. To do so, lab experiments were performed using distilled water containing synthetic Caoline. Eight turbidity levels (10-80 NTU), five pH levels (5.5, 6.0, 6.5, 7.0 and 7.5) and five coagulants doses( 5, 10, 20, 30 and 40 mg/l) were used for the jar test. Rapid mixing for all experiments was 380 rpm for one minute and slow mixing was 30 rpm for 20 minutes. Finally, at the end of every experiment, residual turbidity was measured by turbidity meter; in addition, removal efficiency for various conditions was determined by covariance and regression analysis.
Results: The results showed that an increase of aluminum sulfate dose up to 40 mg/l can increase removal efficiency to 99.9%. The highest removal efficiency for ferric chloride occurred at feed dose of 20 mg/l and primary turbidity of 10 NTU, while for PAC the highest removal efficiency (99%) occurred at 40 mg/l. Effect of pH in turbidity removal for all experiments was similar.
Discussion: Finally, it can be concluded that the best coagulant for turbidity removal (pH=5.5-7.5) is aluminum sulfate, because as the coagulant dose rises up the removal efficiency increases significantly. Efficiency removal, also, depends on the initial turbidity.     
متن کامل [PDF 249 kb]   (1400 دریافت)    
نوع مطالعه: پژوهشي |
* نشانی نویسنده مسئول: مرکز تحقیقات توسعه اجتماعی و ارتقا سلامت، دانشگاه علوم پزشکی و خدمات بهداشتی درمانی زاهدان
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Effectiveness of three coagulants of Polyaluminum Chloride, Aluminum Sulfate and Ferric Chloride in turbidity removal from drinking water. ZJRMS. 2008; 10 (1) :9-15
URL: http://zjrms.ir/article-1-145-fa.html

کردمصطفی پور فردوس ، بذرافشان ادریس ، کمانی حسین . بررسی مقایسه ای کارایی منعقد کننده های سولفات آلومینیوم، کلراید فریک و پلی آلومینیوم کلرایددر حذف کدورت از آب آشامیدنی. Zahedan Journal of Research in Medical Sciences. 1387; 10 (1) :9-15

URL: http://zjrms.ir/article-1-145-fa.html



دوره 10، شماره 1 - ( فروردين 1387 ) برگشت به فهرست نسخه ها
Zahedan Journal of Research in Medical Sciences
Persian site map - English site map - Created in 0.05 seconds with 31 queries by YEKTAWEB 3921